Dynaudio IP 17 Specifications Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
12 Dynaudio Owners Manual
Installation
Produce the cut-out (for wall cut-out dimensions see page 16 and page 17).
WARNING: Notice and follow the safety warnings about existing in-wall installations
on page 10!
Installing IP 17 and IP 24
In case you have already unpacked your loudspeakers, continue with step 4,
otherwise start with step 1:
1. Carefully remove front grille by lifting up strips.
2. Un-tighten the screws (Torx 20 bit): IP 17: 6, IP 24: 10
Place the screws into the accessory pack for later use.
3. Carefully remove baffle by lifting up strips. Protect the baffle in the original packing.
4. Make sure the gasket on the rear side is in correct position.
5. To put the frame inside the wall or ceiling cut-out:
a. Un-tighten the screws to bring the dogleg clamps from “locked” position to “loose”
position.
b. Make sure all doglegs are in “loose” position before frame is positioned in the wall.
c. Depending on the wall or ceiling thickness, two different options to turn the
doglegs are available:
– Wall or ceiling thickness 0 – 40 mm (0 – 1.6"): see 5c. (I)
– Wall or ceiling thickness 36 – 65 mm (1.4 – 2.6"): see 5c. (II)
6. Turn the doglegs so they press against the wall by carefully tightening the screws.
Place your hand inside the cavity to control and assure the doglegs movement.
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 27 28

Comments to this Manuals